site stats

Graphtec gl100-n-th

WebDescription. Voltage and Temperature sensor for GL100 Data Loggers. Programmable per channel. Supports K and J type thermocouples (K: -200 to 1370 °C; T: -200 to 400 °C). Measures 20, 50, 100, 200, 500 mV; 1, 2, 5, 10, 20, 50 V; 1-5 V (for 4-20 mA using 250 Ω shunt). May be directly connected to the GL840 Data Logger. http://graphteccorp.com/support/software/instruments.html

Graphtec GS-TH Temperature and Humidity Sensor - Lontek Data …

WebGraphtec GL100-N-TH-DPA-CO2 Data logger with temp/humidity and CO2 sensor. 4.9MB on-board ... Graphtec GL100-N-DPA-AC50A Data logger with AC current sensor with … http://graphteccorp.com/product/gl100/spec.html fish industry in china https://ayscas.net

Graphtec GS-4TSR Operating Manual

WebThe Graphtec GL100-N-DPA-AC200A is a set that comes with the GL100-N compact Data Logger as well as the GS-DAP-AC AC Current Sensor Adapter, and the GS-AC200A AC Current Sensor. Its body allows users to switch sensors and terminals for … WebThe Graphtec GL100-N-LXUV-DPA-TH is modular type that is able to support variety measurement by exchanging the input module. Multiple sensors and the input terminal are available for corresponding to the application. fish in dry dog food

PetitLOGGER GL100 GRAPHTEC

Category:Graphtec GL100-N-TH - Electronic Test Equipment

Tags:Graphtec gl100-n-th

Graphtec gl100-n-th

Sensor Input Terminal / Adapter - Instrumart

WebAlarm (1 channel), solid state switch with optical isolation (Optocoupler, Max. load is the 30 V, 50 mA) Interface to PC. USB (micro USB B type connector), Wireless LAN (WLAN) in … WebView and Download Graphtec GS-DPA instruction manual online.

Graphtec gl100-n-th

Did you know?

WebGL100 Main Unit, Standard Model. Required to Use with Sensor Units or Input Adapters. Real-time data capturing. Display the captured data value to the LCD in real-time and save the monitoring values. PC and smart mobile device software available. Industry-specific software: agriculture, logistics, power. Built-in memory: 4.9 MB. WebSettings Graphtec B-514 DC power cable, 2 meters remove Graphtec GL100-WL-CO2 Data Logger with Carbon Dioxide Sensor remove Graphtec GL100-WL-TH Data Logger with Temperature Humidity Sensor remove Graphtec GL100-N-4TSR Data Logger with Thermister Input Terminal remove Graphtec GL100-N-4VT Data Logger with Voltage …

WebThe Graphtec GL100-N-TH is a set that comes with the GL100-N compact Data Logger as well as the GS-TH Temperature and Humidity sensor. Its body allows users to switch sensors and terminals for measuring various signals. The main body dimension is a slight 2.6 in. wide x 3.93 in. tall x 1.06 in. thick (66 mm x 100 mm x 27 mm). ... WebThe Graphtec GL100-N-LXUV-DPA-TH is modular type that is able to support variety measurement by exchanging the input module. Multiple sensors and the input terminal …

WebGL100-WL-TH Data Logger with Temperature Humidity Sensor (-20-85'C, 0.0-100.0RH) WLAN model. 4.9MB on-board memory. It is modular type that is able to support variety measurement by exchanging the input module. Multiple sensors and the input terminal are available for corresponding to the application. Easy measurement by multifunction input. Web15 rows · GRAPHTEC. TOP; English ... Item Model number Description; PetitLOGGER …

http://www.graphteccorp.com/product/gl100/supply.html

WebCustom Designed Pelican Case for the GL240 (with Graphtec Logo) N/A: Discontinued. Replaced by: B-536US-840R. B-536US-240R: Custom Designed Pelican Case for the GL240 (with Graphtec Logo). Revised to fit rubber protective cover. ... GL100-N-LXUV-DPA-TH: Data logger with temp/hudmity and Light/UV sensor. 4.9MB on-board memory, … can a veteran\u0027s spouse get medical benefitsWebWireless LAN (in GL100-WL) Standards: IEEE802.11b, Communication distance: approx. 40 m. * It varies by the condition of the LAN. Real-time transfer rate is up to 500ms. The WLAN is able to disable. (It is enabled in the factory default setting) Storage device. Built-in memory: RAM (Approx. 4.9 MB) External memory: microSD memory card. fish industry in indiaWebGraphtec GS-AC50A AC current sensor, Clamp-on type (max. 50 A AC),use with GS-DAP-AC module Graphtec GL100-N-TH Data logger with Temp./Humidity sensor (-20-85ºC, 0.0-100.0%RH), 4.9MB on-board memory, micro-SD memory slot, USB PC interface, LCD display Datalogger Graphtec GL900 8-Channel Multifunction fish industry statisticsWebIf you need more information please contact your Graphtec Europe sales representative or contact us at: Email: [email protected] Tel: +31 (0)23 568 3800 Office hours: Monday to Friday 09:00 - 17:00. ... GS-TH: Compatible with Instrument: GL100-N, GL100-WL: Short Description: Temp./Humidity Sensor: Related Products. fish industry in kenyaWebGL100-N & GS-TH Voltage/Temp. Set: GL100-N-4VT GL100-N & GS-4VT Acceleration Set: GL100-N-3AT GL100-N & GS-3AT Thermistor Set: GL100-N-4TSR ... Graphtec. The SDK will be available at beginning 2015. Confirm temperature accumulation, humidity deficit, solar radiation, ultraviolet rays as part of the vital indicators for ... can a veteran wear a military uniformWebGraphtec GL100-N-TH-DPA-CO2 Data logger with temp/humidity and CO2 sensor. 4.9MB on-board ... Graphtec GL100-N-DPA-AC50A Data logger with AC current sensor with max 50A current sensor. ... Graphtec GL100-N-DPA-AC100A Data logger with AC current sensor with max 100A current senso ... fishinechen gmail.comWebDec 2, 2015 · The Graphtec GL100-N-TH is a set that comes with the GL100-N compact Data Logger as well as the GS-TH Temperature and Humidity sensor. Its body allows … fishineart